Contact Us

For an up to date, competitive quote contact us today!

help centre

Harlequin 10000BFS Bunded Standard BioDiesel Fuel Station

 

Harlequin 10000BFS Bunded Standard BioDiesel Fuel Station

The Harlequin 10000BFS is the largest capacity plastic bunded biodiesel Fuel Station available through RPM Fuels and Tanks.

From £9,435.00 + VAT

£11,322.00Inc VAT

Description
FAQs

Technical Information:

Length:                             3265 mm
Width:                                2800 mm
Height:                              3350 mm
Weight:                             725 kg
Working Capacity:          10100 litres
Maximum Capacity:    9595 litre

Product Summary:

 

The large capacity Harlequin 10000BFS Bunded Standard BioDiesel Fuel Station is capable of storing biodiesel to B100 (100% biodiesel) and is the perfect biodiesel refuelling tank for agricultural, commercial, industrial and haulage premises. This bunded biodiesel storage tank comes complete with its own biodiesel transfer pump, 6 metres of biodiesel delivery hose, automatic shut off biodiesel nozzle and a digital flow meter plus much more, all housed within a lockable cabinet. The Harlequin 10000BFS Bunded Standard BioDiesel Fuel Station meets or exceeds all the latest Environment Agency and Oftec requirements, meeting industries needs to safely and securely store biodiesel in an environmentally friendly manner. Harlequin Bunded Biodiesel Fuel Stations have also been purpose designed for the storage of Diesel fuel in accordance with EN14214 plus The National Summer & Winter Requirements in the UK and RoI  for CFPP*

Specifications:

  • Full sized lockable cabinet housing:
  • 2" fill point with screw on dust cap, offset for ease of use
  • 4" inspection aperture complete with cover
  • 2" internal tank vent
  • Built in bund warning alarm
  • Remote wireless remote oil tank contents gauge with overfill warning alarm
  • LRC overfill prevention capability
  • 240 volt biodiesel transfer pump
  • 6 metres biodiesel delivery hose
  • Automatic shut off biodiesel nozzle
  • 10 micron fuel filtration system
  • Digital Fuel flow meter
  • Built in cabinet light

EXTRA COST OPTION:

Piusi Fuel Management System capable of managing up to 80 users via means of electronic keys. Supplied complete with 10 user keys and a Managers Key for data transfer to a PC or laptop, extra user keys available at extra cost upon request. Please note that this option cannot be fitted to the Harlequin 10000BFS Bunded Standard BioDiesel Fuel Station as an after market option.

Installation:

All Harlequin Bunded Biodiesel Fuel Station Diesel Storage and Dispensing Tanks must be installed by a competent person in accordance with statutory requirements. Barriers are recommended to protect Diesel Storage and Dispensing Tanks from vehicular impact. OFTEC and British Standard BS5410 require that all fuel and oil storage tanks should be installed upon a base of adequate strength that extends a minimum of 300mm beyond the maximum dimensions of the tank. All electrical connections should be undertaken only by a competent, independently accredited electrician. RPM Fuels and Tanks and Clarehill Plastics Limited / Harlequin Oil Tanks will not be responsible for fuel tank installations that do not comply with these requirements.

Pricing & Delivery:

Prices quoted include delivery to anywhere on mainland UK and Northern Ireland but excludes offshore islands and locations. Deliveries will be made by articulated lorry and it is the customers responsibility to ensure safe and adequate access plus off loading. Off loading of heavy items should be made by fork lift or similar heavy lifting equipment. If there is any doubt about delivery access or off loading please contact us to discuss the options available. Please allow a minimum of 10 working days for delivery.

* 1) CFPP is the Cold Filter Plug Point which indicates the temperature at or below which a fuel may begin to cause operational problems. British Standard BS EN14214 and Irish Standard IS EN14214 states Summer and Winter requirements within the UK and Republic of Ireland as -5 degrees Celsius and -15 degrees Celsius respectively.

 

Q. Is there a difference between the types of tanks?

A. Yes, there are lots of differences between the types of oil storage tanks and these are also available in a variety of sizes.

• Single skin tanks (non bunded) are used more in residential situations rather than commercial. However, a bunded version may be required in a residential situation dependant on the results of a risk assessment, to prevent any pollution from occurring.
• A bunded tank is a tank within a tank or a tank surrounded by a protective wall. Bunded tanks are used to prevent pollution and accidental spillage, containing any leaks within the second tank. Normally used in commercial surroundings.
• Double skinned tanks are like bunded tanks, but possess two protective walls with a small gap between.

These files include useful information regarding the safe installation and operation of our products. Please download and review regularly.